Public Function log_subcase_resrch(ByVal subcase_id As String, _
ByVal action_type As String, ByVal note_str As String, _
ByVal int_use As String, ByVal log_date As String, _
ByVal research_time As Long, ByVal user_name As String, _
ByVal new_stat As String, ByVal cmit_title As String, _
ByVal cmit_notes As String, ByVal cmit_due As String, _
ByVal cmit_prior As Long, ByVal cmit_to As Boolean, _
ByVal gen_time_bombs As Boolean, ByVal int_fld1 As String, _
ByVal int_val1 As Long, ByVal int_fld2 As String, _
ByVal int_val2 As Long, ByVal str_fld1 As String, _
ByVal str_val1 As String, ByVal str_fld2 As String, _
ByVal str_val2 As String, ByVal date_fld1 As String, _
ByVal date_val1 As String) As Integer
Public Function log_subcase_resrch_list(ByVal subcase_id As String, _
ByVal action_type As String, ByVal note_str As String, _
ByVal int_use As String, ByVal log_date As String, _
ByVal research_time As Long, ByVal user_name As String, _
ByVal new_stat As String, ByVal cmit_title As String, _
ByVal cmit_notes As String, ByVal cmit_due As String, _
ByVal cmit_prior As Long, ByVal cmit_to As Boolean, _
ByVal gen_time_bombs As Boolean, _
Optional fld_list As Variant, Optional type_list As Variant, _
Optional val_list As Variant) As Integer
Description
These APIs are used to create a research log against a subcase. The APIs allow for the assigning of notes, internal use only text, and an action type. The research time (in seconds) is specified. For example, a 5 minute log would be 300 seconds. A new status can be set for the subcase with this API. Additional fields can also be set as well as a time bomb (for the phone log), which allows notifications to be generated based on the event.
Optionally, you can also set a commitment with the note log. If you wish to set a commitment, you MUST set the commitment due date (cmit_due) and the commitement title (cmit_title). The commitment title usually comes from the user-defined list "COMMITMENT", but it does not have to for this API. Any string is acceptable. The other commitment fields are optional. You can add notes to the commitement , and a prior warning. Also, you must set if the commitment is to the contact or by the contact. The contact for the case is always used for the commitment contact.
The objid of the created log is returned in the FCCS object variable ret_objid.
The objid of the commitment log record is returned in the FCCS object variable ret_objid2.
The objid of the status change record is returned in the FCCS object variable ret_objid3.
Parameters
Parameter Name Required? Description
subcase _id Yes The subcase to create the log for
action_type No The research log action type code value. If left blank, default code is used
notes No The research log text
int_use No Internal use only information
log_date No The date the log was created. If left blank, the current time is used
research_time Yes The length of the research time in seconds
user_name No The user who created the log. If left blank, the current user performs
the logging
new_stat No New status for the subcase. If blank (""), no status change is performed
cmit_title No Title of the commitment. If blank, no commitment is generated
cmit_notes No If generating a commitment, optional notes for the commitment (max length
of 255)
cmit_due No When is the commitment due. If blank, no commitment is generated
cmit_prior No How long (in seconds) before the commitment is due should a warning
business rule notification be fired. If set to 0, no warning is generated
cmit_to Yes Is the commitment made to the customer (=True), or by the customer
(=False). If no commitment is to be generated, this value is ignored
gen_time_bombs Yes Should a time_bomb be generated (for notifications/business rules).
int_fld1, int_fld2 No Names of additional fields to write
str_fld1, str_fld2
date_fld1
int_val1, int_val2 No Values for the additional fields. These values are only used if the
str_val1, str_val2 corresponding field name field is filled with a valid field name
date_val1
fld_list Yes List of additional field names to write. List must be present, but does not
need to have any items in the list
type_list Yes List of additional field data types to write. List must be present, but does not
need to have any items in the list
val_list Yes List of additional field values to write. List must be present, but does not
need to have any items in the list
log_objid Output This field returns the objid of the newly created log object
Returns
Value Meaning
0 No errors
-1 Research log time is negative
-2 Cannot find the specified subcase
-3 Cannot find the specified user
-4 Cannot find the RESEARCH LOG activity string
-5 Cannot find the research log action type string
-6 Cannot find the employee record for the specified user
-7 The supplied status is invalid for the current condition
-8 A commitment is to be created, but the title is blank
-9 The prior warning is negative
-10 The commitment due date is before the log creation date
-11 Cannot find the COMMIT activity string
-12 Could not find the com_tmplte for WARNING
-13 Could not find the com_tmplte for COMMITMENT
Examples
· Create a research log of 4 minutes for subcase number 'C154-1'. Set the notes for the log, and no other information. Generate a time bomb.
Field version:
JavaScript:
var ret_int = fccs.log_subcase_resrch("C154-1", "", "Some notes", "",
"", 240, "", "", "", "", "", 0, true, true,
"", 0, "", 0, "", "", "", "", "", "");
Visual Basic:
Dim ret_int As Integer
ret_int = fccs.log_subcase_resrch("C154-1", "", "Some notes", "", _
"", 240, "", "", "", "", "", 0, True, True, _
"", 0, "", 0, "", "", "", "", "", "")
List version:
JavaScript:
var ret_int = fccs.log_subcase_resrch_list("C154-1", "", "Some notes", "",
"", 240, "", "", "", "", "", 0, true, true);
Visual Basic:
Dim ret_int As Integer
ret_int = fccs.log_subcase_resrch_list("C154-1", "", "Some notes", "", _
"", 240, "", "", "", "", "", 0, True, True)
· Create a 3 minute research log for subcase number '2-2'. Set action code of 'Engineering Research', some note text, and internal use only text. Have the note logged by marty on November 23, 1997 at 10PM. Change the status to "Working". Also, create a commitment for January 1, 1999 at 8:00AM, with a title, notes, and a prior warning of 1 hour (with the commitment being made by the contact). Generate some additional fields, but do not generate a time bomb.
Field version:
JavaScript:
var ret_int = fccs.log_subcase_resrch("2-2", "Engineering Research",
"Some notes", "Internal use", "11/23/97 22:00:00", 180,
"marty", "Working", "Commit title", "Commit notes",
"1/1/1999 8:00:00", 3600, false, true, "x_close_int1",
1, "x_close_int2", 456, "x_summary2", "More text",
"", "", "x_other_date", "1/1/99");
Visual Basic:
Dim ret_int As Integer
ret_int = fccs.log_subcase_resrch("2-2", "Engineering Research", _
"Some notes", _
"Internal use", "11/23/97 22:00:00", 180, "marty", _
"Working", "Commit title", "Commit notes", "1/1/1999 8:00:00", _
3600, False, True, "x_close_int1", 1, "x_close_int2", 456, _
"x_summary2", "More text", "", "", "x_other_date", _
"1/1/99")
List version:
JavaScript:
var fld_list = Server.CreateObject("FCFL.FCList");
var type_list = Server.CreateObject("FCFL.FCList");
var val_list = Server.CreateObject("FCFL.FCList");
fld_list.AppendItem("x_close_int1");
type_list.AppendItem("Long");
val_list.AppendItem ("1");
fld_list.AppendItem("x_close_int2");
type_list.AppendItem("Long");
val_list.AppendItem ("456");
fld_list.AppendItem("x_summary2");
type_list.AppendItem("String");
val_list.AppendItem("More text");
fld_list.AppendItem("x_other_date");
type_list.AppendItem("Date");
val_list.AppendItem("1/1/99");
var ret_int = fccs.log_subcase_resrch_list("2-2", "Engineering Research",
"Some notes", "Internal use", "11/23/97 22:00:00", 180,
"marty", "Working", "Commit title", "Commit notes",
"1/1/1999 8:00:00", 3600, false, true, fld_list,
type_list, val_list);
Visual Basic:
Dim ret_int As Integer
Dim fld_list As New List
Dim type_list As New List
Dim val_list As New List
fld_list.AppendItem "x_close_int1"
type_list.AppendItem "Long"
val_list.AppendItem Trim(Str$(1))
fld_list.AppendItem "x_close_int2"
type_list.AppendItem "Long"
val_list.AppendItem Trim(Str$(456))
fld_list.AppendItem "x_summary2"
type_list.AppendItem "String"
val_list.AppendItem "More text"
fld_list.AppendItem "x_other_date"
type_list.AppendItem "Date"
val_list.AppendItem "1/1/99"
ret_int = fccs.log_subcase_resrch_list("2-2", "Engineering Research", _
"Some notes", "Internal use", "11/23/97 22:00:00", 180, _
"marty", "Working", "Commit title", "Commit notes", _
"1/1/1999 8:00:00", 3600, False, True, fld_list, _
type_list, val_list)